High Voltage Differential Probe SS-320

Supports measurements based on other than 0V. Ideal for measuring the actual operating waveform of inverter switching devices from commercial power supplies

Compatible with Maximum Differential Operating Voltage 1.4kV
(DC + AC peak)

Application example

When ViewGoII DS-5600A Series power supply option is used

When external power supply is used

Specifications

SS-320
Frequency bandwidthDC to 100MHz (-3 dB) *See derating characteristics
Attenuation50:1, 500:1
Accuracy±2 %(20ºC ~ 30ºC)
* When the input impedance is connected to an oscilloscope of 1MΩ ±1%
DC CMRR-70dB* at 500VDC input voltage
AC CMRR-80 dB(50 Hz/60 Hz) / -50 dB(100 kHz) / -50 dB(1 MHz)
Transmission delay12.5 ns (500:1, typical), 13.5 ns (50:1, typical)
Input R // CFrom each input to GND, 4MΩ or more // 7.0pF or less
Between inputs8MΩ or more // 3.5pF or less
Maximum differential operating voltage±1,400 V(DC+AC peak, 500:1), ±140 V(DC+AC peak, 50:1)
Maximum in-phase operating voltage±1,400V (DC + AC peak), or ±1,000Vrms
Maximum non-destructive
(Differential mode, in-phase mode)
±1,500 V(DC+AC peak), 1,300 Vrms
Maximum output voltage rangeWhen connected to an oscilloscope of ±2.8V * 1MΩ ±1%
Output offsetAdjustable with other devices to be combined
Connector output side/input sideBNC model/Special 6-core connector
Full length2,000 mm ±30 mm
Power cable length1,000 mm ±20 mm
Input lead length405 mm ±5 mm
Weight450g or less
Warranty temperature range0°C to +50°C (no condensation)
Operating temperature and humidity-10°C to +50°C (no condensation)/80% RH or less (at 40°C)
AccessoriesCrocodile clip (red, black) 1 each, plunger hook clip (red, black) 1 each, instruction manual

Option

  • Dedicated power supply PS-25
  • Dedicated power supply DS-579 (ViewGoII dedicated option)
  • Dedicated power supply is not included

Accessory external dimensions

Crocodile clip (standard accessory)

Plunger hook clip (standard accessory)