Featuring a user-friendly “one-key, one-action” system.Our high-cost-performance counters are available in a lineup of three variations!
The universal counter SC-7205A features frequency, cycle, time interval, pulse width, phase, frequency ratio, duty ratio, cumulative count, and peak voltage measurements for easy, versatile measurement. As a basic piece of measurement equipment for development work and technical education, they are also ideal for introduction to production and inspection lines.
Easy operations with single key strokes for each action.
Easy to see fluorescent display tube. Detailed information is shown on a 5 × 7-dot display. * The full spelling display guide strongly supports operations.
Auto-trigger function that does not require setting the trigger level. Manual settings are also possible.
Comparator and statistical operation function make it easy to improve the efficiency of line inspection work.
Unit conversion (rpm, speed, etc.) is possible using the scaling operation function.
It is easy to check the waveform amplitude by measuring the peak voltage of the input signal.
Streamline routine inspection work by saving/recalling panel setup.
RS-232 interface for full remote control 200 data/sec real-time transfer possible * GPIB interface SC-701 (factory option)
Highly expandable options Comparator output with digital I/O (SC-702). External trigger input. * A generous output of 150mA and 50V that can be used as it is for line monitoring equipment.
Measurement function (selection guide)
Measurement function
Gate
Equipped model
Internal
EXT-B
MANUAL
SGL
SC-7207H
SC-7206H
SC-7205A
FREQ-A
Frequency
○
○
×
○
○
○
○
FREQ-B
Frequency
○
×
×
○
○
×
○
FREQ-LINE
Frequency
△
×
×
×
○
×
○
FREQ-C
Frequency
○
○
×
×
○
○
×
PERI-A
Period
○
○
×
○
○
○
○
DUTY-A
Duty
○
×
×
○
○
○
○
P.W-A
Pulse width
○
×
×
○
○
○
○
TOT-A
Addition counting
○
○
○
×
○
○
○
T.INT A-B
Interval
○
×
×
○
○
×
○
FREQ A/B
Frequency ratio
○
×
×
×
○
×
○
PHAS A-B
Phase
○
×
×
○
○
×
○
Peak voltage A
-
-
-
-
○
○
○
Peak voltage B
-
-
-
-
○
×
○
○… Selectable × … Disabled △… Disabled for 1ms, 10ms
Various interfaces and options
GPIB Interface SC-701 (for SC-7205A)
Factory Option. Please order at the same time as the main unit. The universal counters SC-7207H, SC-7206H, SC-7205H, and SC-7205A have a built-in SC-701 (SC-7207H, SC-7206H are standard equipment), which enables remote setting and external transmission of measurement result data related to measurement reset, measurement function, time base, calculation, etc. by an external GP-IB controller.
Electrical and mechanical specifications are in accordance with IEEE 488.1.
It has the following interface functions for GPIB. SH1, AH1, T5, L4, SR1, RL1, PP0, DC1, DT1, C0
It has a REMOTE/LOCAL status LED indicator.
Fully remote control supported (except for some functions such as on/off of the power switch and remote related settings.)
The following settings are possible through the SYSTEM menu of UTILITY.
The 31 types of device addresses from 0 to 30 can be selected at will.
One of CR+LF or LF can be selected as the delimiter.
Digital I/O SC-702 (for SC-7207H, SC-7206H, SC-7205H, SC-7205A)
Factory Option. Please order at the same time as the main unit. By integrating the SC-702 (digital I/O), the universal counter SC-7205A can control the start of measurement and output the comparator operation result (open collector). By connecting lamps, etc. to the exterior, you can easily visualize parts sorting and inspection results.
Timing chart
Control signal
Details
/TRIG C-MOS input
Start the measurement with an L pulse of 10ms or more during the /BUSY = Z period. The /TRIG signal during the /BUSY = L period is invalid.
/BUSY open collector output
Measuring L (output transistor on), non-measuring Z (output transistor off)
/HI, /LO, /GO Open collector output
One place is L (output transistor on) according to the comparator operation result
Otherwise, Z (output transistor off)
Output terminal maximum setting
Withstand voltageDC50V
Withstand current DC150mA
Frequency responseDC~1kHz
Input terminal maximum rating
Withstand voltageDC5V
Frequency responseDC~1kHz
High stability reference oscillator SC-703A
Factory Option. Please order at the same time as the main unit.
Item
Performance
Oscillation frequency
±0.05ppm +25°C as reference 0°C to +40°C range
Rise time
±±0.05ppm 10 minutes after power on based on the frequency 1 hour after power on
Change over time (/day)
±0.02ppm Value after 72 hours based on 48 hours after power is turned on
Change over time (/month)
±0.1ppm Value after one year based on 10 days after power is turned on
Other options
型名
概要
Appearance
SC-525
USB-RS converter. By adopting a cross cable and using the RS connector as a female connector, it is possible to directly connect the USB port and the measurement equipment. You can use an external controller (usually using a PC) to perform the same operations as when you manually control using button operation on the main unit. Not only operations, but also measurement result data collection is possible (interface specifications are the same as the standard RS-232).
Counts from 0 to 4,294,967,295 when the scaling operation is OFF
Measurement error
±1 [count] (only when the gate is opened and closed)
Peak voltage measurement
The voltage amplitude of the CH-A or CH-B measured signal is measured and displayed in real time.
Specifications
Measurement frequency
150Hz ≤ Input frequency ≤ 50MHz
Measurement speed
2 seconds or less
Measurement range
ATT OFF
-2.50V to +2.50V (10mV resolution)
ATT ON
-50.0V to +50.0V (100mV resolution)
Measurement error
ATT OFF
10% ±50mV of displayed value (for sine waves)
ATT ON
No specification
CH-A/B input terminal
Specifications
Maximum input voltage
200V(DC+ACpeak)
Impedance
Approx. 1MΩ//20pF or less
Coupling
AC or DC
Low pass filter
None or 10kHz
Attenuator
None or 26dB (1/20)
Trigger level
Measurement range
ATT OFF
-2.50V to +2.50V (10mV resolution)
ATT ON
-50.0V to +50.0V (100mV resolution)
Measurement accuracy (0~+40ºC)
ATT OFF
10% ±30mV of the set value (however, +2 to -2V is ±3%)
ATT ON
10% ±300mV of the set value (however, +40 to -40V is ±3%)
Operating range
ATT OFF
-2.50V~+2.50Vpeak
ATT ON
-50.0V~+50.0Vpeak
nput sensitivity
Manual trigger
ATT OFF
30mVrms(DC~230MHz)
ATT ON
0.6Vrms(DC~230MHz)
Auto trigger
ATT OFF
200mVrms (10kHz to 230MHz for sine waves)
ATT ON
4mVrms (10kHz to 230MHz for sine waves)
Measurement error
10MHz STD IN
BNC terminal for inputting more stable reference frequencies from the outside.
Specifications
Input frequency
10MHz±50Hz(±5ppm)
Input amplitude
1Vrms~5Vrms Threshold = 0V
Input resistance
Approx. 6.4kΩ
Input coupling
AC
10MHz STD OUT /(MARKER OUT)
BNC terminal for outputting internal reference oscillator or marker signals. A marker signal is a signal assuming the luminance modulation (Z axis) of the analog oscilloscope. It is valid when the function is the SGL gate of the time interval (T.INT A→B) and phase (PHAS A→B), and the period from the start of the CH-A measurement to the start of the CH-B measurement is output = L.
Specifications
Output
CMOS level
Reference frequency output
The 10MHz stability is the same as the standard transmitter on the main unit
Marker output
Bandwidth 5MHz Output L for the actual measurement period.
Output interface
Specifications
RS-232
Standard equipment
GPIB
Factory option(SC-701)
Digital I/O
Factory option(SC-702)
Environmental conditions
Preheating time:At least 60 minutes
Operating temperature/humidity 0ºC to +40ºC/85% R.H or less (no condensation)
Storage temperature/humidity -20ºC to +60ºC/90% R.H or less (no condensation)
Reference oscillator
Equipped as standard. Can be output to the 10MHz OUT BNC terminal on the rear of the main unit.
Oscillation frequency 10MHz
Temperature characteristics ±2.5ppm/equipment ambient temperature 0ºC~+40ºC
Change over time ±1.0ppm/year
Change in power supply conditions and power supply voltage (factory option)
Power supply voltage 100VAC ±10% Change in power supply voltage (factory option):110~120V or 220~240V
Power supply frequency 50Hz, 60Hz, 400Hz
Power consumption 31VA MAX (at 100VAC with optional SC-701 and SC-702)
Size, mass
Size:Approx. 210W × 99H × 353L mm (excluding options and protruding parts)
Mass:4.0kg or less (when equipped with optional SC-701, SC-702, SC-703A)
Accessories
Power cord (1), Instruction manual (CD-ROM) (1), User’s Guide (1)
FAQ
Please click below for FAQs regarding this product.If your questions are not resolved by the FAQs, please contact us via email using the “Inquiries” link above.
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional
Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes.The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.