Power Curve Tracer CS-10000 Series

Ideal for measuring the characteristics of power devices
Supports ultra high voltage and high current

Line up

  • CS-10400
    Maximum peak voltage:10kV (+DC only)
    Maximum peak current:4,000A
  • CS-10800
    Maximum peak voltage:10kV (+DC only)
    Maximum peak current:8,000A
  • CS-12800
    Maximum peak voltage:12kV (+DC only)
    Maximum peak current:8,000A
  • CS-15800
    Maximum peak voltage:15kV (+DC only)
    Maximum peak current:8,000A

Pulse Unit Option

An option to prevent the change or destruction of characteristics due to heat generation. The rise time can be switched in three stages, the pulse width can be set from 1ms to 20ms, and the interval time can be set from 100ms to 2s. (This option will be added to the inside of the curve tracer, so please order it at the same time as the main unit, or if you are already using the main unit, we will take it back to our factory.)

 Specifications

Collector supply HV mode specification

ModelCS-10000 Series common
Mode/polarityFull-wave rectification/ + – , DC/ + – , LEAKAGE/ + – , AC
Maximum peak voltage3kV300V30V
Maximum peak current
(maximum peak
pulse current*)
75mA
(150mA*)
750mA
(1.5A*)
7.5A
(15A*)
Maximum peak power120mW / 1.2W / 120W / 390W (Cannot be set when using the maximum peak voltage of 3kV)
  •  The maximum instantaneous current value that can be generated (varies depending on the target to be measured and conditions)
      measurement should be less than or equal to the maximum peak current value.

Collector supply UHV mode specification

ModelCS-10400/10800CS-12800CS-15800
Mode / polarityDC / +
Maximum peak voltage10kV12kV15kV
Maximum peak current400mA266mA266mA
Maximum peak power40W / 400W / 4kW32W / 320W / 3.2kW40W / 400W / 4kW

Collector supply UHC mode specification

ModelCS-10400CS-10800 / 12800 / 15800
Mode/polarityPulse/ + –
Maximum peak voltage60V40V60V
Maximum peak current4,000A400A40A8,000A4,000A400A40A
Maximum peak power60kW6kW600W80kW60kW6kW600W
Pulse width50µs~900µs, 50µs~1,200µs (at 8,000A) (10µs resolution)
Measurement pointThe measurement point can be specified (10µs resolution)
Vertical axis range100mA~1,000A/div

Common specification

Specification
Loop correctionHardwareCorrection of floating capacitance between collector supply and ground
SoftwarePseudo-looping through software optimization
Step generatorOffsetSetting range-10 ~ +10 x STEP AMPLITUDE setting
Resolution1% of STEP AMPLITUDE setting
Current modeRange50nA to 200mA per step, 21 steps 1-2-5 switching
Maximum current2A
Maximum voltage10V or more
Voltage modeRange50mV to 2V per step, 6 steps 1-2-5 switching
Maximum current500mA~(~8V), 200mA~(~15V), 10mA~(~40V)
Maximum voltage±40V
Step rate2x 50Hz or 60Hz (1x in AC mode), pulse interval in HC mode
Pulse stepPulse width50µs~400µs(10µs step)
When in HC mode, the pulse width is 100µs wide before and after the pulse of the collector supply
Number of steps0 to 20 steps
AUX outputRangeOff, -40V to +40V (variable in 100mV steps)
Measurement modeREPEAT、STOP/SINGLE、SWEEP
Vertical axis
(full scale 10div)
Collector currentRangeHV mode:1µA/div to 2A/div, 20 steps 1-2-5 switching (HC mode is not included)
Accuracy2% + 0.05 x VERT/div of readout
To this, add the loop correction error for the following maximum peak voltages
0.5µA(30V), 1µA(300V), 6µA(3kV), 12µA(5kV)
Specify at least 10% of the maximum peak voltage for 30V, 300V, and 3kV, and at least 30% for 5kV
Emitter current
(LEAKAGE)
Range1nA/div~2mA/div,20 step 1-2-5 switching
(Collector supply mode is LEAKAGE)
Accuracy2% + 0.05 x VERT/div + 1nA or less of readout
Horizontal axis
(full scale 10div)
Collector voltageRangeHC mode:50mV/div to 5V/div, 7 steps 1-2-5 switching (HV mode is not included)
Accuracy2% + 0.05 x HORIZ/div or less of readout
Base/
emitter voltage
Range50mV/div~5V/div, 7 step 1-2-5 switching
Accuracy2% + 0.05 x HORIZ/div or less of readout
DisplayDisplay8.4-inch TFT LCD
Number of data points1,000 points/trace (AC, full wave rectification)
20~1,000 points/trace (SWEEP mode)
Trace displayPoint interpolation display, dot display
AveragingOFF, 2 to 255 times
PersistenceOFF, SHORT, LONG, Infinite length
Save internal waveform(REF)4-Panel
カーソル測定DOTVert, Horiz, β or gm
fLINEVert、Horiz、1/grad, intercept
FREEVert, Horiz, β or gm
WINDOWVert, Horiz, β or gm in the WINDOW area
Data save/readMemorySetup:256 pcs, REF:4 screens
External memoryUSB1.1:Setup, Waveform, Screen Hardcopy (BMP, TIFF, PNG)
RemoteEquipped with remote 10BASE-T/100BASE-TX 1 port via LAN connection
Power supplyAC200V single-phase 50/60Hz, maximum operating power:10kVA
External dimensions(mm) , WeightApprox. 1,110W x 1,216H x 1,150D (excluding protrusions and accessories),
approx. 370kg (excluding accessories)

Options

CS-301

CS-302

Test fixture S
Standard with CS-3100 main unit

Test fixture M
CS-3200 CS-3300 Standard with each main unit

CS-303

CS-304

Test fixture M
CS-5100 / CS-5200 / CS-5300 Standard with each main unit

Test fixture M
Standard with CS-5400 main unit

CS-305

CS-307 / CS-307H

Test fixture L
Signal light, thermo switch, cooling fan, equipped with LED light, interlock

テスト・フィクスチャ
CS-307 :For CS-3000/CS-5000 (excluding CS-5400)
CS-307H : For CS-5400

CS-306

CS-308

Prober cable
For CS-3000/CS-5000 (excluding CS-5400)

Prober cable
For CS-5400

PA-3020 / 3040 / 4030

CS-310

Hot plate
Non-isolated type

Test fixture for thermal streamer

CS-521 / CS-522 / CS-523

IE-1310

Adapter for thermal streamer
Supported package:
CS-521 :TO (CS-501A heat-resistant support))
CS-522 : TO-263-3 (D2PAK)
(CS-503 heat resistant)
CS-523 : TO-252-3 (CS-504 heat-resistant support)

CS setup controller
Ideal for production lines because the settings can be switched without any menu operation on the main unit.

Test adapter option

CS-500

Heat resistant TO socket

Test adapter (1 standard with main unit)

200℃, 350A(500μs)

For TSSOP14

CS-501A

*Test fixture CS-301 cannot be used

TO type test adapter
This is a socket suitable for TO type packages (3 terminals).
It can be used with lead spacing from 1.52mm to 4.57mm.

CS-502

CS-503

AXIAL type adapter
1kV / 1A MAX

TO-263-3 (D2APK) type adapter

CS-504

CS-505

TO-252-3 type adapter

TO-263-7 type adapter

CS-506

CS-507

TO-252-5 type adapter

SC-70-3 (SOT-323-3) type adapter

CS-508

CS-509

SMD tip type adapter

SC-59A (SOT-23-3) type adapter

CS-510

SC-62 (SOT-89) type adapter

CS-700 Series options

CS-701

CS-702A

Switch control module
It is an indispensable unit that collectively controls each unit from the semiconductor parameter measurement software CS-810 by connecting it with a PC by Ethernet.
One unit can control up to 8 units. By assigning an IP address, parallel operation using multiple units (up to 10 units) is also possible.

LV relay unit
300V/7.5A/30A(Pulse) 10CH

CS-703A

CS-704A

HV relay unit
5kV/0.5A 10CH

HC relay unit
2kV/7.5A/1,500A(Pulse) 10CH

CS-705

CS-706

HV/HC switch unit
With 5kV/1,000A (Pulse) HV/HC switching (manual) function for CS-3200/3300/5200/5300

Extension unit
If you wish to use 5kV/1,000A (Pulse) CS-5400, you will need to modify it

CS-707

CS-708

Gate/short unit
It is possible to shorten the G-E or C-G intervals of elements that are not being measured during measurement of a 6 in 1 module.

Curve tracer side: 300V/7.5A/15A (Pulse) Device side: 5kV/7.5A/15A(Pulse) 10CH

HV-HC relay unit
5kV/7.5A/1,500A(Pulse) 2CH

CS-709

CS-710

HV-HC relay unit
5kV/7.5A/1,500A(Pulse) 4CH

HV/HC switch unit
With 5kV/1,500A (Pulse) HV/HC switching (manual) function for CS-5400

Cable Options

CS-001 (red 10 pcs)

CS-002 (black 10 pcs)

Small crocodile clip
This is a small crocodile clip that can be attached to a wire set.

Small crocodile clip
This is a small crocodile clip that can be attached to a wire set.

CS-003

CS-004

High voltage wire red 5 pcs set

Wire black 5 pcs set

CS-005

CS-006

Standard lead set
This is a lead set that comes as a standard accessory with the main unit.

Cables for high current 20cm x 2 sets
Standard accessory with the CS-5400 main unit

CS-007

Cables for high current 30cm x 2 sets
Standard accessory with the CS-10400 or CS-10800 main unit

Software

CS-800

CS-801

CS-810

Semiconductor parameter search body software
Software option to be integrated and used in the main unit.
Embedded Software

Double sweep
Software option to be integrated and used in the main unit.
Embedded Software

Semiconductor parameter measurement PC software
This is the software used on the PC (sold separately) when the SC-800 is installed on the main unit.