Universal Counter SC-7205A

Featuring a user-friendly “one-key, one-action” system.Our high-cost-performance counters are available in a lineup of three variations!

The universal counter SC-7205A features frequency, cycle, time interval, pulse width, phase, frequency ratio, duty ratio, cumulative count, and peak voltage measurements for easy, versatile measurement. As a basic piece of measurement equipment for development work and technical education, they are also ideal for introduction to production and inspection lines.

  • Easy operations with single key strokes for each action.
  • Easy to see fluorescent display tube. Detailed information is shown on a 5 × 7-dot display.
    * The full spelling display guide strongly supports operations.
  • Auto-trigger function that does not require setting the trigger level. Manual settings are also possible.
  • Comparator and statistical operation function make it easy to improve the efficiency of line inspection work.
  • Unit conversion (rpm, speed, etc.) is possible using the scaling operation function.
  • It is easy to check the waveform amplitude by measuring the peak voltage of the input signal.
  • Streamline routine inspection work by saving/recalling panel setup.
  • RS-232 interface for full remote control
    200 data/sec real-time transfer possible
    * GPIB interface SC-701 (factory option)
  • Highly expandable options
    Comparator output with digital I/O (SC-702). External trigger input.
    * A generous output of 150mA and 50V that can be used as it is for line monitoring equipment.

Measurement function (selection guide)

Measurement functionGateEquipped model
InternalEXT-BMANUALSGLSC-7207HSC-7206HSC-7205A
FREQ-AFrequency×
FREQ-BFrequency×××
FREQ-LINEFrequency××××
FREQ-CFrequency×××
PERI-APeriod×
DUTY-ADuty××
P.W-APulse width××
TOT-AAddition counting×
T.INT A-BInterval×××
FREQ A/BFrequency ratio××××
PHAS A-BPhase×××
Peak voltage A
Peak voltage B×

○… Selectable × … Disabled △… Disabled for 1ms, 10ms

Various interfaces and options

GPIB Interface SC-701 (for SC-7205A)

Factory Option. Please order at the same time as the main unit.
The universal counters SC-7207H, SC-7206H, SC-7205H, and SC-7205A have a built-in SC-701 (SC-7207H, SC-7206H are standard equipment), which enables remote setting and external transmission of measurement result data related to measurement reset, measurement function, time base, calculation, etc. by an external GP-IB controller.

  • Electrical and mechanical specifications are in accordance with IEEE 488.1.
  • It has the following interface functions for GPIB.
    SH1, AH1, T5, L4, SR1, RL1, PP0, DC1, DT1, C0
  • It has a REMOTE/LOCAL status LED indicator.
  • Fully remote control supported (except for some functions such as on/off of the power switch and remote related settings.)

Equipped model

SC-7207H , SC-7206H:Standard equipment
SC-7205A , SC-7205H:Option

Address settings

The following settings are possible through the SYSTEM menu of UTILITY.

  • The 31 types of device addresses from 0 to 30 can be selected at will.
  • One of CR+LF or LF can be selected as the delimiter.

Digital I/O SC-702 (for SC-7207H, SC-7206H, SC-7205H, SC-7205A)

Factory Option. Please order at the same time as the main unit.
By integrating the SC-702 (digital I/O), the universal counter SC-7205A can control the start of measurement and output the comparator operation result (open collector). By connecting lamps, etc. to the exterior, you can easily visualize parts sorting and inspection results.

Timing chart

Control signal

Details
/TRIG C-MOS inputStart the measurement with an L pulse of 10ms or more during the /BUSY = Z period.
The /TRIG signal during the /BUSY = L period is invalid.
/BUSY open collector outputMeasuring L (output transistor on), non-measuring Z (output transistor off)
/HI, /LO, /GO
Open collector output
One place is L (output transistor on) according to the comparator operation result
Otherwise, Z (output transistor off)

Output terminal maximum setting

  • Withstand voltageDC50V
  • Withstand current DC150mA
  • Frequency responseDC~1kHz

Input terminal maximum rating

  • Withstand voltageDC5V
  • Frequency responseDC~1kHz

High stability reference oscillator SC-703A

Factory Option. Please order at the same time as the main unit.

ItemPerformance
Oscillation frequency±0.05ppm
+25°C as reference 0°C to +40°C range
Rise time±±0.05ppm
10 minutes after power on based on the frequency 1 hour after power on
Change over time (/day)±0.02ppm
Value after 72 hours based on 48 hours after power is turned on
Change over time (/month)±0.1ppm
Value after one year based on 10 days after power is turned on

Other options

型名概要Appearance
SC-525USB-RS converter. By adopting a cross cable and using the RS connector as a female connector, it is possible to directly connect the USB port and the measurement equipment. You can use an external controller (usually using a PC) to perform the same operations as when you manually control using button operation on the main unit. Not only operations, but also measurement result data collection is possible (interface specifications are the same as the standard RS-232).