High Voltage Probe HV-P60A/HV-P30A

Probes with excellent waveform quality for high voltage measurement of up to 60kV and 30kV (2 types)

High Voltage Probe HV-P60A

  • Oscilloscope measurement of high voltage waveforms up to 60kV DC and 80kV single pulse
  • Frequency band DC to 50MHz broadband
  • Maintenance free with the use of silicon rubber, Guaranteed stable withstand voltage

High Voltage Probe HV-P30A

  • Oscilloscope measurement of high voltage waveforms up to 30kV DC and 40kV single pulse
  • Frequency band DC to 50MHz broadband
  • Maintenance free with the use of silicon rubber.
    Guaranteed stable withstand voltage

Specifications

HV-P60AHV-P30A
Maximum input voltageDC:60kV, single pulse:80kV (standard pulse wave:tip length = 1µs/tail length = 40µs)DC:30kV, single pulse:40kV (standard pulse wave:tip length = 1µs/tail length = 40µs)
Frequency bandwidthDC~50MHz -3dB
Rise time7ns or less
Input RCR1000MΩ±5%100MΩ±5%
C5pF±2pF7pF or less
Attenuation2000:1 ±5%1000:1 ±5%
Waveform distortion±5% (10℃ to 35℃) * However, except for ringing and overshooting
Cable lengthApprox. 4mApprox. 3m
Connector typeBNC type
Connectable
Oscilloscope input RC
R1MΩ
C10pF~40pF
SizeSee exterior view
Operating temperature/Storage temperature-10℃~+50℃
WeightProbe main unit:Approx. 2.0kg, overall:Approx. 3.2kg (including accessories)Probe main unit:Approx. 1.3kg, overall:Approx. 2.5kg (including accessories)
AccessoriesOutput cable (including matching box), clamping bracket, tip, earth lead, adjustment screwdriver, storage bag
OptionHigh pressure probe stand (made-to-order product) SK-301
SK-301 is used for HV-P60A/HV-P60/HV-P30A/HV-P30.
Change the probe receptacle up and down (for HV-P60A/HV-P60/HV-P30A/HV-P30) before mounting.

Characteristic curve

High voltage probe HV-P60A maximum input voltage and frequency (sine wave)

A passive probe that connects to an oscilloscope to measure high voltage waveforms. The frequency range is DC-50MHz, the maximum input voltage is DC60kV, and the attenuation ratio is 2000:1.

High voltage probe HV-P30A maximum input voltage and frequency (sine wave)

Maximum input voltage and frequency (sine wave) [HV-P60A]

Maximum input voltage and frequency (sine wave) [HV-P30A]

Exterior view

HV-P60A