Power Curve Tracer CS-10000 Series

Ideal for measuring the characteristics of power devices
Supports ultra high voltage and high current
Line up
- CS-10400
Maximum peak voltage:10kV (+DC only)
Maximum peak current:4,000A - CS-10800
Maximum peak voltage:10kV (+DC only)
Maximum peak current:8,000A - CS-12800
Maximum peak voltage:12kV (+DC only)
Maximum peak current:8,000A - CS-15800
Maximum peak voltage:15kV (+DC only)
Maximum peak current:8,000A

Pulse Unit Option
An option to prevent the change or destruction of characteristics due to heat generation. The rise time can be switched in three stages, the pulse width can be set from 1ms to 20ms, and the interval time can be set from 100ms to 2s. (This option will be added to the inside of the curve tracer, so please order it at the same time as the main unit, or if you are already using the main unit, we will take it back to our factory.)

Specifications
- Collector supply HV mode specification
- Collector supply UHV mode specification
- Collector supply UHC mode specification
- Common specification
Collector supply HV mode specification
| Model | CS-10000 Series common | ||
|---|---|---|---|
| Mode/polarity | Full-wave rectification/ + – , DC/ + – , LEAKAGE/ + – , AC | ||
| Maximum peak voltage | 3kV | 300V | 30V |
| Maximum peak current (maximum peak pulse current*) | 75mA (150mA*) | 750mA (1.5A*) | 7.5A (15A*) |
| Maximum peak power | 120mW / 1.2W / 120W / 390W (Cannot be set when using the maximum peak voltage of 3kV) | ||
- The maximum instantaneous current value that can be generated (varies depending on the target to be measured and conditions)
measurement should be less than or equal to the maximum peak current value.
Collector supply UHV mode specification
| Model | CS-10400/10800 | CS-12800 | CS-15800 |
|---|---|---|---|
| Mode / polarity | DC / + | ||
| Maximum peak voltage | 10kV | 12kV | 15kV |
| Maximum peak current | 400mA | 266mA | 266mA |
| Maximum peak power | 40W / 400W / 4kW | 32W / 320W / 3.2kW | 40W / 400W / 4kW |
Collector supply UHC mode specification
| Model | CS-10400 | CS-10800 / 12800 / 15800 | |||||
|---|---|---|---|---|---|---|---|
| Mode/polarity | Pulse/ + – | ||||||
| Maximum peak voltage | 60V | 40V | 60V | ||||
| Maximum peak current | 4,000A | 400A | 40A | 8,000A | 4,000A | 400A | 40A |
| Maximum peak power | 60kW | 6kW | 600W | 80kW | 60kW | 6kW | 600W |
| Pulse width | 50µs~900µs, 50µs~1,200µs (at 8,000A) (10µs resolution) | ||||||
| Measurement point | The measurement point can be specified (10µs resolution) | ||||||
| Vertical axis range | 100mA~1,000A/div | ||||||
Common specification
| Specification | |||
|---|---|---|---|
| Loop correction | Hardware | Correction of floating capacitance between collector supply and ground | |
| Software | Pseudo-looping through software optimization | ||
| Step generator | Offset | Setting range | -10 ~ +10 x STEP AMPLITUDE setting |
| Resolution | 1% of STEP AMPLITUDE setting | ||
| Current mode | Range | 50nA to 200mA per step, 21 steps 1-2-5 switching | |
| Maximum current | 2A | ||
| Maximum voltage | 10V or more | ||
| Voltage mode | Range | 50mV to 2V per step, 6 steps 1-2-5 switching | |
| Maximum current | 500mA~(~8V), 200mA~(~15V), 10mA~(~40V) | ||
| Maximum voltage | ±40V | ||
| Step rate | 2x 50Hz or 60Hz (1x in AC mode), pulse interval in HC mode | ||
| Pulse step | Pulse width | 50µs~400µs(10µs step) When in HC mode, the pulse width is 100µs wide before and after the pulse of the collector supply | |
| Number of steps | 0 to 20 steps | ||
| AUX output | Range | Off, -40V to +40V (variable in 100mV steps) | |
| Measurement mode | REPEAT、STOP/SINGLE、SWEEP | ||
| Vertical axis (full scale 10div) | Collector current | Range | HV mode:1µA/div to 2A/div, 20 steps 1-2-5 switching (HC mode is not included) |
| Accuracy | 2% + 0.05 x VERT/div of readout To this, add the loop correction error for the following maximum peak voltages 0.5µA(30V), 1µA(300V), 6µA(3kV), 12µA(5kV) Specify at least 10% of the maximum peak voltage for 30V, 300V, and 3kV, and at least 30% for 5kV | ||
| Emitter current (LEAKAGE) | Range | 1nA/div~2mA/div,20 step 1-2-5 switching (Collector supply mode is LEAKAGE) | |
| Accuracy | 2% + 0.05 x VERT/div + 1nA or less of readout | ||
| Horizontal axis (full scale 10div) | Collector voltage | Range | HC mode:50mV/div to 5V/div, 7 steps 1-2-5 switching (HV mode is not included) |
| Accuracy | 2% + 0.05 x HORIZ/div or less of readout | ||
| Base/ emitter voltage | Range | 50mV/div~5V/div, 7 step 1-2-5 switching | |
| Accuracy | 2% + 0.05 x HORIZ/div or less of readout | ||
| Display | Display | 8.4-inch TFT LCD | |
| Number of data points | 1,000 points/trace (AC, full wave rectification) 20~1,000 points/trace (SWEEP mode) | ||
| Trace display | Point interpolation display, dot display | ||
| Averaging | OFF, 2 to 255 times | ||
| Persistence | OFF, SHORT, LONG, Infinite length | ||
| Save internal waveform(REF) | 4-Panel | ||
| カーソル測定 | DOT | Vert, Horiz, β or gm | |
| fLINE | Vert、Horiz、1/grad, intercept | ||
| FREE | Vert, Horiz, β or gm | ||
| WINDOW | Vert, Horiz, β or gm in the WINDOW area | ||
| Data save/read | Memory | Setup:256 pcs, REF:4 screens | |
| External memory | USB1.1:Setup, Waveform, Screen Hardcopy (BMP, TIFF, PNG) | ||
| Remote | Equipped with remote 10BASE-T/100BASE-TX 1 port via LAN connection | ||
| Power supply | AC200V single-phase 50/60Hz, maximum operating power:10kVA | ||
| External dimensions(mm) , Weight | Approx. 1,110W x 1,216H x 1,150D (excluding protrusions and accessories), approx. 370kg (excluding accessories) | ||
Options
CS-301
CS-302
Test fixture S
Standard with CS-3100 main unit

Test fixture M
CS-3200 CS-3300 Standard with each main unit

CS-303
CS-304
Test fixture M
CS-5100 / CS-5200 / CS-5300 Standard with each main unit

Test fixture M
Standard with CS-5400 main unit

CS-305
CS-307 / CS-307H
Test fixture L
Signal light, thermo switch, cooling fan, equipped with LED light, interlock

テスト・フィクスチャ
CS-307 :For CS-3000/CS-5000 (excluding CS-5400)
CS-307H : For CS-5400

CS-306
CS-308
Prober cable
For CS-3000/CS-5000 (excluding CS-5400)

Prober cable
For CS-5400

PA-3020 / 3040 / 4030
CS-310
Hot plate
Non-isolated type

Test fixture for thermal streamer

CS-521 / CS-522 / CS-523
IE-1310
Adapter for thermal streamer
Supported package:
CS-521 :TO (CS-501A heat-resistant support))
CS-522 : TO-263-3 (D2PAK)
(CS-503 heat resistant)
CS-523 : TO-252-3 (CS-504 heat-resistant support)

CS setup controller
Ideal for production lines because the settings can be switched without any menu operation on the main unit.

Test adapter option
CS-500
Heat resistant TO socket
Test adapter (1 standard with main unit)

200℃, 350A(500μs)

For TSSOP14
CS-501A
*Test fixture CS-301 cannot be used

TO type test adapter
This is a socket suitable for TO type packages (3 terminals).
It can be used with lead spacing from 1.52mm to 4.57mm.

CS-502
CS-503
AXIAL type adapter
1kV / 1A MAX

TO-263-3 (D2APK) type adapter

CS-504
CS-505
TO-252-3 type adapter

TO-263-7 type adapter

CS-506
CS-507
TO-252-5 type adapter

SC-70-3 (SOT-323-3) type adapter

CS-508
CS-509
SMD tip type adapter

SC-59A (SOT-23-3) type adapter

CS-510
SC-62 (SOT-89) type adapter

CS-700 Series options
CS-701
CS-702A
Switch control module
It is an indispensable unit that collectively controls each unit from the semiconductor parameter measurement software CS-810 by connecting it with a PC by Ethernet.
One unit can control up to 8 units. By assigning an IP address, parallel operation using multiple units (up to 10 units) is also possible.

LV relay unit
300V/7.5A/30A(Pulse) 10CH

CS-703A
CS-704A
HV relay unit
5kV/0.5A 10CH

HC relay unit
2kV/7.5A/1,500A(Pulse) 10CH

CS-705
CS-706
HV/HC switch unit
With 5kV/1,000A (Pulse) HV/HC switching (manual) function for CS-3200/3300/5200/5300

Extension unit
If you wish to use 5kV/1,000A (Pulse) CS-5400, you will need to modify it

CS-707
CS-708
Gate/short unit
It is possible to shorten the G-E or C-G intervals of elements that are not being measured during measurement of a 6 in 1 module.
Curve tracer side: 300V/7.5A/15A (Pulse) Device side: 5kV/7.5A/15A(Pulse) 10CH

HV-HC relay unit
5kV/7.5A/1,500A(Pulse) 2CH

CS-709
CS-710
HV-HC relay unit
5kV/7.5A/1,500A(Pulse) 4CH

HV/HC switch unit
With 5kV/1,500A (Pulse) HV/HC switching (manual) function for CS-5400

Cable Options
CS-001 (red 10 pcs)
CS-002 (black 10 pcs)
Small crocodile clip
This is a small crocodile clip that can be attached to a wire set.

Small crocodile clip
This is a small crocodile clip that can be attached to a wire set.

CS-003
CS-004
High voltage wire red 5 pcs set

Wire black 5 pcs set

CS-005
CS-006
Standard lead set
This is a lead set that comes as a standard accessory with the main unit.

Cables for high current 20cm x 2 sets
Standard accessory with the CS-5400 main unit

CS-007
Cables for high current 30cm x 2 sets
Standard accessory with the CS-10400 or CS-10800 main unit

Software
CS-800
CS-801
CS-810
Semiconductor parameter search body software
Software option to be integrated and used in the main unit.
Embedded Software
Double sweep
Software option to be integrated and used in the main unit.
Embedded Software
Semiconductor parameter measurement PC software
This is the software used on the PC (sold separately) when the SC-800 is installed on the main unit.