4 Channel Data Logger GL2000

CAT III 600V Compatible High-voltage High-speed Measurements
GL2000 is a high-voltage isolated 4 channels data logger that corresponds to CAT III 600 V and up to 600 V rms measurement, all channel isolated simultaneously at 1 MS/s and high-speed sampling. It can measure of factory equipment and high voltage measurement.
The DP-581H thermal printer can be connected and data can be handed over on the spot. It makes prevent data falsification and prevent data tampering.
Inside, 4MW/ch internal RAM and 8GB internal flash memory. Outside, SD memory card and USB memory storage media according to the sampling interval and situation.

High speed 1 MS/s simultaneous sampling with isolated input
GL2000 is equipped with an isolated input mechanism to protect signals from interferences caused by noise from other channels. 16-bit A/D converter adopted to achieve hi-speed and hi-resolution measurement.

Simultaneous sampling
GL2000 utilizes simultaneous sampling to eliminate slowdown in sampling rate by using multiple A/D converters in simultaneous sampling method.
External sampling
Sampling of the logger is performed in sync with an external device using an external signal input.
Multifunction Input with CAT III Measurement Category

CAT III 600 V is compatible with measuring power supply circuit in an equipment that captures power directly from the distribution panel.

Measures abnormalities in a repeated waveform by effectively measuring the corresponding RMS value
- In 1000 Vrms range, Crest Factor is up to 1.41
Maximum rated safety voltage: 600 V rms, Peak voltage: 850V - In other range, Crest Factor is up to 2.0

Large Easy-to-read 7-inch LCD

- Y-T waveform monitor screen
- Digital monitor screen
- Past waveform monitor screen
- XY graph monitor screen
Quick and Easy Set Up Process
Simple operation with cursor and enter keys, and menu-driven operation with six pre-set menu screens: AMP, DATA, DISP, TRIG, I/F (Interface) and OTHER.

Equipped with three types of options for power source
- AC adapter
- DC input
- battery pack
Option
- Storage case (B-581)
Supports Large Built-in RAM (4MS/ch) and Built-in Flash (8GB)

Built-in Flash memory
- 4 MW samples/ch built-in RAM
- 8 GB built-in Flash memory
External Storage
- SD Card memory
- USB Flash memory
Convenient Data Recording Functions
- Memory division function
- Ring / Relay mode
- Save & replay data in CSV format
- Data backup and hot swaps
- Auto save function
- Search function
Equipped with Ethernet (LAN) and USB Interface to Communicate with PC

Convenient function with LAN (Ethernet interface) capability
- Web server function
- FTP server function
- NTP client function
- Email sending function
USB Drive Mode to Easily Transfer Files to PC
- USB drive mode
- Scale : mm
Tolerance : +/- 3 mm
SENSOR & CABLE
- Main unit specifications
- Input Specifications
- Software specifications
- Standard accessories
- Battery pack B-569 (option) Specifications
- Humidity Sensor B-530 (option) Specifications
- Dimensions
Main unit specifications
| Item | Description | ||
| Display (LCD) | Size | 7-inch TFT color LCD (WVGA: 800 x 480 dots) | |
| Information | Waveform in Y-T with digital values, Enlarged waveforms, Digital values and Real-time statistical result values, XY graph | ||
| Language | English, French, German, Spanish, Russian, Chinese, Korean, Japanese | ||
| Interface to PC | Type | Ethernet (10 BASE-T/100 BASE-TX), USB2.0 | |
| Function | Data transfer to PC (up to 1 ms sampling), Control command to GL2000 | ||
| Ethernet functions | Web server function, FTP server function, NTP client function, DHCP client function, Email send function | ||
| USB function | USB mode (File transfer and deletion from built-in flash and SD on GL2000) | ||
| Trigger function | Trigger action | Start or stop capturing data by triggering | |
| Trigger source | • Start: Off, Measured signal, Alarm, External, Scheduled time, Scheduled day, Elapsed time • Stop: Off, Measured signal, Alarm, External, Scheduled time, Scheduled day, Elapsed time | ||
| Combination | Level OR, Level AND, Edge OR, Edge AND | ||
| Threshold | • Analog (*1): High or Low in level mode, Rising or Falling in edge mode, Window-in, Window-out • Logic: H or L (4-channel signal pattern) • Pulse: High or Rising, Low or Falling, Window-in, Window-out | ||
| Storage deice | Built-in RAM | Four million samples for each channel • Memory partition: 4 M samples x 1 bank, 2 M sample x 2 banks, 1 M samples x 4 banks, 500 k samples x 8 banks • Capturing data points: Specified 10 to 4000000 • Data type: Captured data • Auto-save: Transfer captured data to other devices after capturing is completed (It can be enabled or disabled) | |
| Built-in Flash | 8GB • Data type: Captured data, Condition settings, Screen copy | ||
| External USB (*2) | Support USB Flash memory device (*3) by USB2.0 Type A port, Single port, No memory capacity limit • Data type: Captured data, Condition settings, Screen copy | ||
| External SD CARD (*2) | Support SDHC memory card (up to 32 GB) by SD Card slot, Single slot • Data type: Captured data, Condition settings, Screen copy | ||
| Capturing mode | Off (Normal) | Save data between start to stop | |
| Ring (*4) | Save most recent data of specified number • Destination: Built-in RAM, Built-in Flash, USB or SD • Number of capturing data: 1000 to 10000000 data (*5) • Sampling: up to 1 MS/s (interval 1 μs) in built-in RAM, up to 1 kS/s (interval 1 ms) with GBD format in other device, up to 100 S/s (interval 10 ms) with CSV format in other device | ||
| Relay | Save data to multiple files with specified capturing time or file size (up to 4 GB) until recording data is stopped • Destination: Built-in Flash, USB or SD • Sampling: up to 1 kS/s (interval 1 ms) with GBD format, up to 100 S/s (interval 10 ms) with CSV format | ||
| Data backup | Interval (*6) | Off, 1, 2, 6, 12, 24 hrs., specific time, or any time with key operation • Sampling: up to 1 kS/s (interval 1 ms) with GBD format, up to 100 S/s (interval 10 ms) with CSV format | |
| File destination (*6) | Built-in Flash, USB or SD, FTP | ||
| Data format (*6) | GBD (binary) or CSV (test) | ||
| Hot-swapping external memory | Hot-swapping USB or SD Flash memory with key operation during data backup | ||
| Calculation function | Statistical | Real-time: Display digital and statistical values at the same time • Function: Maximum, Minimum, Peak-to-peak (P-P), Average | |
| Replay: Statistical values between cursors in replay captured data • Function: Maximum, Minimum, Peak-to-peak (P-P), Average, RMS | |||
| Between channels | Addition, subtraction, multiplication and division for two analog inputs (only in GBD format) | ||
| Operating environment | 0 to 40 ºC when driven by AC adapter or battery, 5 to 85 % RH (non condensed) | ||
| Size | 7-inch TFT color LCD (WVGA: 800 x 480 dots) | ||
| Power source | AC adapter: 100 to 240 V AC, 50/60 Hz DC power: 8.5 to 24 V DC (required cable option B-514) Battery pack: Two battery packs (option B-569) required | ||
| Power consumption | AC adapter (in 240 V AC) | Approx. 39 VA (59 VA while charging battery) with disabling screen saver Approx. 34 VA (55 VA while charging battery) with enabling screen saver | |
| DC drive (24 V) | Approx. 0.5 A (0.81 A while charging battery) with disable screen saver Approx. 0.43 A (0.76 A while charging battery) with enabling screen saver | ||
| DC drive (12 V) | Approx. 1 A (Cannot charge battery) with disable screen saver Approx. 0.85 A (Cannot charge battery) with enabling screen saver | ||
| DC drive (8.5 V) | Approx. 1.46 A (Cannot charge battery) with disable screen saver Approx. 1.22 A (Cannot charge battery) with enabling screen saver | ||
| External dimensions [W×H×D] | Approx. 260 x 161 x 83 mm (with the cover) | ||
| Weight | Approx. 1.7 kg (the cover is attached, AC adapter and battery are not included) | ||
| Vibration resistance | Compatible with JIS Vibration test method for automobile Type 1 Class A (Vibration durability test: 5 m/s²) | ||
- It can set for each channel.
- File size of captured data is up to 4GB in each file.
- Standard USB memory devices are required.
- Required minimum capturing time is 15 seconds in GBD format, 30 seconds with CSV format.
- When using built-in RAM, 10 to 4000000 data
- * The CSV format and FTP server are available with firmware version 1.14 or rater.
– When the RING mode or external pulse synchronization sampling is selected for recording, the backup function is not available.
– When there are meany number of active channels, the sampling time is fast, or the backup interval is long, it may take time to closing the data file after recording stops because the size of the data to be backed up becomes large.
– When backup is enabled and data file format is specified with CSV format, SD memory card exchange (hot-swapping) and RELAY recording are not available.
Input Specifications
| Item | Description | ||||
| Analog input specifications | Number of input channels | 8 channels | |||
| Type of input terminal | Isolated BNC connector and Screw terminal (M3.5 screw) | ||||
| Input method | All channels isolated unbalanced input, Simultaneous sampling | ||||
| Sampling speed (interval) | 1 M Samples/s to 1 Sample/min (1 μs to 1 min) and External • Sampling interval: 1, 2, 5, 10, 20, 50, 100, 200, 500 μs, 1, 2, 5, 10, 20, 50, 100, 200, 500 ms, 1, 2, 5, 10, 20, 30 sec, 1 min * When using built-in RAM: 1 μs to 1 min, using other storage: 1 ms to 1 min | ||||
| Frequency response | DC ~ 200 kHz(+1 / -4dB) | ||||
| Measurement range | Voltage (DC) | 20, 50, 100, 200, 500 mV 1, 2, 5, 10, 20, 50, 100, 200, 500V, 1-5V F.S. | |||
| DC-RMS (DC coupling and rms value meas.) | 10, 25, 50, 100, 250, 500 mV rms, 1, 2.5, 5, 10, 25, 50, 100, 250 V rms F.S. • Crest Factor: up to 2 • Frequency response: 20 Hz to 10 kHz • Measures the accumulated value of the DC and AC components in effective value, that is a true-RMS | ||||
| Temperature | Thermocouple: K, J, E, T, R, S, B, N, W (WRe5-26) | ||||
| Humidity | 0 to 100 % RH – using the humidity sensor (option B-530) | ||||
| Filter (Low pass) | Off, Line (1.5 Hz), 5, 50, 500 Hz, 5, 50 kHz (at -3dB, -6dB/oct) | ||||
| A/D converter | 16-bit (effective resolution: 1/40000 of the measuring full range) | ||||
| Maximum input voltage | Between (+) – (-) terminal | 20 mV to 2 V range: 30 V DC, 5 V to 500 V range: 500 V DC | |||
| Between channels (-) – (-) terminals) | 60Vp-p | ||||
| Between channel – GND | 60Vp-p | ||||
| External input & output signal specifications | External input/output | Input | Logic or Pulse (4 channels), Trigger or Sampling (1 channel) | ||
| Output | Alarm (4 channels) or Trigger (1 channel) with Alarm (3 channels) | ||||
| Pulse measurement | Pulse count detection cycle | 10 μs to 1 hr. (Set separately from analog signal sampling interval) | |||
| Maximum pulse input | Maximum input frequency: 100 kHz, Maximum count number: 15 M count (24 bit counter) | ||||
| Measurement mode | Rotation: Counts the number of pulses per detection cycle and then converts measured value to rotation in rpm • Span: 0 to 500 M rpm/F.S. | ||||
| Accumulating: Accumulates the number of pulses count per detection cycle from the start of measurement • Span: 0 to 20 M count/F.S. (Span is set automatically) | |||||
| Instant: Counts the number of pulses per detection cycle • Span: 0 to 20 M count/F.S. | |||||
| External sampling input | Executes sampling of measurement signal with each external sampling signal • Maximum input frequency: 100 kHz (Time error: 1 μs or less) | ||||
| Output signal | Alarm output | Open collector (pull-up to 5 V with 10 kΩ resistor) • Maximum load is the 24 V and 100 mA | |||
| Trigger output | When a trigger is detected, output terminal releases approximately 500 μs width pulse (Low active) | ||||
Software specifications
| Item | Description | |
| Supported OS | Windows11 | |
| Functions | Control GL980 and GL2000, Real-time data capture, Replay data, and Data format conversion | |
| Supported device | 1 unit of GL980 or GL2000 | |
| Settings control | Input condition, Capturing condition, Trigger/Alarm condition, other | |
| Transfer of captured data | In memory capturing with GL2000 | Transfer the captured data to a PC sequentially while data is saved in built-in RAM on GL2000 • Sampling interval: 1 μs to 1 min |
| In real time capturing | Transfer the captured data to a PC while data is saved in built-in flash memory, SD or USB on GL2000 • Sampling interval: 1 ms to 1 min saved in GBD and CSV format | |
| Displayed information | Analog waveform, Logic waveform, Pulse count waveform, Digital value | |
| Display mode | Waveform in Y-T with digital values, Enlarged waveforms, Statistical calculation result values and history, XY graph | |
| File operation | Converting data format to CSV from GBD binary with data between cursors or all data | |
| Past data screen function | Displays the current data or past part of data by switching. Available at sampling speed 1 kS/s to 1 S/m (1 ms to 1 min sampling interval) | |
| Statistical calculation | Maximum, Minimum, Average and Peak-to-peak (p-p) value during data capturing | |
Standard accessories
- AC adapter with power cable
- Ferrite core (attach to cable for radiation reduction)
- Screws (M3.5) for input terminal
- Tilt stand set (including mounting screws M4)
- TO ENSURE SAFE AND CORRECT USE
- Notice
Battery pack B-569 (option) Specifications
| Item | Description |
| Capacity | 7.2V/2900mAh |
| Battery operating time | Approx. 3 hrs. in displayed signal (LCD: max. brightness) Approx. 5 hrs. in screen saver mode (no display) * When two battery packs are installed in GL2000. Condition: 1 sample per second (1 s), saving captured data to built-in Flash, use two fully charged battery packs, temperature is 25 ºC |
| Method of charging | Charging on GL2000 |
| Charging time | Approx 10 hrs. (charging two batteries) |
| Other functions | • If an AC power failure occurs, it will automatically switch from the AC adapter to the battery pack. (AC adapter priority use) • When the voltage of the battery pack reaches low, the measurement is automatically stopped after saving data file preserving the accumulated data. |
Humidity Sensor B-530 (option) Specifications
| Item | Description | |
|---|---|---|
| Allowable temperature range | -25~80℃ | |
| Allowable humidity range | 0~100% RH | |
| Relative humidity measurement accuracy | ±3% RH(5~98% RH at 25℃) | |
| Method | Capacitance method | |
| Relative humidity measurement accuracy (5 to 98%) | Measurement environment | Measurement accuracy |
| 0~10℃ | ±5% RH | |
| 10~20℃ | ±4% RH | |
| 20~30℃ | ±3% RH | |
| 30~40℃ | ±4% RH | |
| 40~50℃ | ±5% RH | |
| 50~60℃ | ±6% RH | |
| 60~70℃ | ±7% RH | |
| 70~80℃ | ±8% RH | |
| * Measurement accuracy at 60℃ or more is a reference value. | ||
| Response time | 15 sec. (90% response when membrance filter is installed) | |
| Sensor output | DCO~1V | |
| External dimensions | Φ14 x 80 mm (excluding cable) | |
| Cable length | 3m | |
| Sensor power source | DC+5V~+16V | |
| Power consumption | approx. 4 mA | |
Dimensions
GL2000 External Dimensions with cover (rubber protector)

- Scale : mm
Tolerance : +/- 5 mm
GL2000 External Dimensions

Software for high performance and easy operation
Allows connections of Graphtec’s midiLOGGER series
The GL-Connection software included with GL7000, GL2000, GL980,GL860 and GL260 can control devices.
It is an integrated application software for the GL series, the GL900, GL860, GL840, GL820, GL260, GL240 and GL220 can also be connected and controll
GL7000 Plus / GL2000 / GL980
GL860 / GL840 / GL260 / GL240
GLT400 / GL900 /GL820/ GL220

Various measurement screens
The measurement signal can be displayed in various types of screens adapted to applications.

Multi-window function, measured signal can be displayed in various forms
Multi-window function
The GL-Connection software supports up to 2000 channels and up to 20 units of the GL series. It splits up to 4 windows and each window can display different format for easy monitoring signal in large channels.

When the unit of GL series is connected to the PC via Ethernet or USB, the GL-Connection software can manage a various information such as the data in capturing, data in the free running – displaying data without saving – and data in saved file.
The GL-Connection software can also display the data saved on the PC.

Tab function
The tab function allows you to manage the screen so that it can be intuitive and easy monitoring. Screen displayed in multi-window can split using the tab and selected items can be displayed. Items to be displayed can be set in detail, such as the GL body level, individual input module level, the specified channel, and other settings.
- Copy of the entire tab

- Copy of the channel

- Move of the tab

- Cursor synchronization

- Release of remote lock of GL7000

Integrated application software for the GL series
When the software is used with the GL7000, it can be controlled and displayed the data including the FFT measurement. When other GL series is used, the software has mainly the waveform viewing function and have also the function to control basic items. Data captured by other GL series is compatible with the GL-Connection and APS software.

Connection of multiple units and the integrating function of the saved data
GL-connection software will be able to manage multiple units in a mixed condition of the GL series. Data integration function allows you to understand the overall situation immediately by creating single file at the same time axis from multiple data file saved by each unit.
| Connection method | Model | Model mixed | Control of Start/Stop | Data integration |
|---|---|---|---|---|
1.Multiple unit connection![]() | GL7000 Plus GL2000 GL980 GL860 GL840 GL260 GL240 GLT400 | Yes | It make operation for each unit. | It makes manually after completing the data capture. |
| 2.Link connection (simultaneous) ![]() | GL7000 Plus GL2000 GL980 GL860 GL840 GL260 GL240 GLT400 | Yes | All units make the action in a single operation. * The timing of the action is maybe synchronized. | It makes automatically after completing the data capture. It can also make manually. |
| 3.Link connection (synchronous) * Sync cable is used to connect each unit. ![]() | GL7000 Plus | No | All units make the action with full synchronization in a single operation. | It makes automatically after completing the data capture. It can also make manually. |
| 4.Mixed connection, mixing of No.1 to No.3 ![]() | GL7000 Plus GL2000 GL980 GL860 GL840 GL260 GL240 GLT400 | Way of operation or action vary by type of connection that is the No.1 to No.3. * Full synchronization can be made when the sync cable is used in the GL7000. | ||
- データ結合の流れ

- The integrated file cannot be created when it exceeds 100 units or 100 channels (analog channel + logic channel).
- Data will be integrated with using fastest sampling speed when the sampling speed in each file is different.
- The data format in integrated data file is the GL7000 format even if GL series is included to capture the data.
Main function of software
| Item | Description | ||
|---|---|---|---|
| GL-Connection (version 2.0 or later) *GL260 (v.2.60 or later) *GL860 (v.2.70 or later) *GLT400 (v.2.50 or later) | Connection | Supported model | GL7000, GL2000, GL980 GL900-4/-8 (Firm. v. 3.01 or later) GL860 GL840 (Firm. v. 1.21 or later) GL820 (Firm. v. 1.08 or later) GL260 GLT400 GL240 (Firm. v. 1.21 or later) GL220 (Firm. v. 1.06 or later) |
| Max. number of unit | 20 | ||
| Max. number of channel | 2000 | ||
| Mixing the USB & LAN | Possible | ||
| Display | Splitting of screen | Up to 4 screens | |
| Group function | Up to 20 groups | ||
GL980_2000-APS | Connection | Supported model | GL2000 / GL980 |
| Max. number of unit | 1 | ||
| Max. number of channel | 4 or 8 | ||
| Mixing the USB & LAN | N/A | ||
| Display | Splitting of screen | No, single screen | |
| Group function | N/A | ||
GL100_GL240_GL840-APS | Connection | Supported model | GL840 / GL240 / GL820 / GL220 / GL100 |
| Max. number of unit | 10 | ||
| Max. number of channel | 1000 | ||
| Mixing the USB & LAN | Possible | ||
| Display | Splitting of screen | No, single screen | |
| Group function | Up to 4 groups | ||
| GL28-APS | Connection | Supported model | GL860 / GL840 / GL260 / GL240 |
| Max. number of unit | 10 | ||
| Max. number of channel | 1000 | ||
| Mixing the USB & LAN | Possible | ||
| Display | Splitting of screen | No, single screen | |
| Group function | Up to 4 groups | ||
| GL220_820-APS | Connection | Supported model | GL820 / GL800 / GL220 / GL200A |
| Max. number of unit | 10 | ||
| Max. number of channel | 500 | ||
| Mixing the USB & LAN | N/A | ||
| Display | Splitting of screen | No, single screen | |
| Group function | Up to 4 groups | ||
| GL900-APS | Connection | Supported model | GL900-4 / GL900-8 |
| Max. number of unit | 1 | ||
| Max. number of channel | 4 or 8 | ||
| Mixing the USB & LAN | N/A | ||
| Display | Splitting of screen | No, single screen | |
| Group function | N/A | ||
Supported model and condition of connection
| Supported model | Connected by USB | Connected by LAN | Wireless LANN | Notice |
|---|---|---|---|---|
| GL7000 | Yes | Yes | N/A | (1) GL series up to 20 units (2) Up to 2000 channels |
| GL2000 / GL980 | Yes | Yes | N/A | |
| GL860 | Yes | Yes | Yes ※ | |
| GL840 | Yes | Yes | Yes ※ | |
| GL260 | Yes | N/A | Yes ※ | |
| GL240 | Yes | N/A | Yes ※ | |
| GLT400 | Yes | Yes | Yes ※ | |
| GL900 | Yes | Yes | N/A | |
| GL820 | Yes | Yes | N/A | |
| GL220 | Yes | N/A | N/A |
- using B-568 option.
- B-568 is available in limited region.
Sampling Limits
High speed sampling is limited by the number of recording channels, connected modules, and the recording destination, etc. Even within the following limits, transmission may be incomplete due to transmission delays with multiple module connections, especially with LAN connections. If this occurs, please reduce the sampling rate. For more details on the GL device limits, please refer to the main module user’s manual on CD-ROM.
GL7000
| Name | Explanation | ||
|---|---|---|---|
Module-based limits (GL device limits) | Voltage module | 1ms | |
| Voltage / Temperatuer module | 10ms | ||
| High Speed Voltage / High Voltage module | 1μs | ||
| DC Strain / Charge module | 10μs | ||
| Logic / Pulse module | Logic: 1 µs / pulse: 100 µs | ||
Recording destination-based limits (GL device limits) | Internal RAM | 1ms | |
| Internal flash | 1ms | ||
| SD card | 1ms | ||
SSD module | 1 to 2 modules:1 µs; however, the pulse runs only until 8ch 3 to 4 modules: 2 µs; however, the pulse is only until 16ch Over 5 modules: 5 µs | ||
| Main module recording format-based limits (GL device limits) | GBD (binary) | 1μs | |
| CSV (Text) | 10ms | ||
| Calculation function-based limits (GL device limits) | 100 ms * The GL device’s calculation function cannot be used with this application. There is no calculation function in this application. | ||
| Ring recording-based limit. (GL device limits) | Ring recording-based limit. (GL device main module limits) When ring recording is on:100ms (Only when Internal Flash, SD card, SSD module) | ||
Transmission-based limits (Application limits) | There are estimated sampling settings for PC recording depending on the volume of data communication. * When connecting through an existing network such as a LAN connection, communication may not be possible within the following limits. In such a case, please use a USB connection, or set a lower sampling rate. Estimated sampling rates | ||
USB connection | GBD (binary) format | 1ms/5Unit | |
| CSV (text) format | 1ms/5Unit | ||
LAN connection | GBD (binary) format | 1ms/5Unit | |
| CSV (text) format | 1ms/5Unit | ||
GL860、GL840、GL260、GL240、GLT400、GL820、GL220
| Name | Explanation | |
|---|---|---|
| Limitations by amplifier (Limitations of the GL module side) | Number of CH available | Fastest sampling |
| 1 | 10ms | |
| 2 | 20ms | |
| 3~5 | 50ms | |
| 6~10 | 100ms | |
| 11~20 | 200ms | |
| 21~50 | 500ms | |
| 51~100 | 1s | |
| 101~200 | 2s | |
| * The number of channels of the GS/WL sensors is not included | ||
| Main module recording format-based limits (GL device limits) | GBD (binary) | 10ms~ |
| CSV (Text) | 100ms~ (※GL860、GL840、GL260、GL240は10ms~) | |
GL2000、GL980
| Name | Explanation | |
|---|---|---|
Recording destination-based limits (GL device limits) | Internal RAM | 1µs |
| Internal flash | 1ms | |
| USB memory | 1ms | |
| Main module recording format-based limits (GL device limits) | GBD (binary) | 1ms~ |
| CSV (Text) | 1ms~ | |
GL900
| Name | Explanation | |
|---|---|---|
| Recording destination-based limits (GL device limits) | Internal RAM | 10us |
| Internal flash | 1ms | |
| USB memory | 1ms | |
| Main module recording format-based limits (GL device limits) | GBD (binary) | 1ms~ |
| CSV (Text) | 10ms~ | |
Functions
| Item | Description |
|---|---|
| Module Settings List | Settings of multiple modules can be displayed simultaneously, and setting conditions can now be saved as CSV data. |
| Remote Lock On/Off Feature | Setting operation is available on GL7000 under control of GL-Connection. |
| Statistics / Display | Display statistical calculation result. Capturing data: Maximum, Minimum, Peak or Average Replaying data: Maximum, Minimum, Peak, Average or RMS in between cursors |
| Check-sum function | It is a function to check data file consistency. The check-sum code is recorded into the file when data file is created by the GL unit. When the content of the file is changed by someone, the check-sum generated from the file does not match with the recorded check-sum, which indicates that the file has been tampered with. * This software and the firmware on the GL unit need to be a version that supporting the check-sum function. |
| File operation | Converts binary data to the CSV data (specific period, all data in one file, multiple files), Creates a new file with compression or by consolidating multiple files. |
| Search function | Search any point on the data. Level: Specific level in any channels Alarm: Occurred alarm in any channel Time: Beginning, center, end of the data, Trigger point, Specific time (absolute, relative), Specific number |
| Warning function | Send e-mail to the specified address when the alarms occur |
PC measurement with standard PC software included (GL980_2000-APS)
There are two types standard software for GL2000 and GL980, the PC software GL980_2000-APS can control GL2000 or GL980 and display measured data, the high-performance software GL-Connection has advanced functions and be used with other device of GL series.
PC measurement with standard PC software included (GL980_2000-APS)
Multiple measurement screens including Y-T waveform, XY chart
Y-T display
Recorded signal is displayed in waveform (Y-T) and digital value for each channel.

Y-T display (Zone mode)
Screen is divided into multiple zone, and channels can be assigned to each zone.

XY display
Four groups of XY charts are displayed.

Easily Connect to the GL2000/GL980 with Quick Set Up Conditions

Convenient features from the GL980_2000-APS software
File combine and bind function
- Superimpose: Data or file recorded on another unit or time can be imported as additional channels when using a SUPERIMPOSE function.
- Link: Captured data in multiple files are connected and saved as new file. It is helpful in reviewing data captured with relay mode.
* Measurement parameters of each file must be the same.
Direct Excel function
The GL980_2000-APS software executes recorded data into a file on PC in real time and exports to a specified Excel file at the same time.
This is a valuable tool in creating report requiring post-process calculation with Excel software.。
Printing function