Isolated Multi-CH data LOGGER GL860

Isolated Multi Channel Data Logger GL860 & 4 Terminals

  • 4 types of input terminals lineup including 30CH for the first time!
  • Expandable from 20ch to max. 200ch, enabling measurement of various phenomena.
  • Compatible with remote control service G-REMOTE.
  • Data recorded by GL860 can be transferred to PLC via Modbus communication.
  • 5 new features:
    Faster sampling interval, Memory loop functions, CH copy function, Alarm history, Inter-CH operation
  • Wireless measurement from your PC is available with the optional wireless LAN unit.

All Channel Isolated / Universal Input, Standalone Multi-Channel

Voltage, temperature, and humidity can be selected for each input channel.
Use EU scaling for other measurement parameters.

Measure voltage

Supports wide operating range (from 20 mV to 100 V)

Measure temperature

Thermocouple: K, J, E, T, R, S, B, N, C(old W:WRe5-26)
RTD*: Pt100・JPt100・Pt1000(IEC751)
(only 3 wire type is supported)
*Please use B-565 for connecting the RTD

Measure current (4 -20 mA)

Shunt resistor (250Ω) is available as an option.
Equipped with a dedicated 1-5V range for the measurement range

Shunt resistance 250Ω (B-551)

*Cannot be used with the screwless terminal

Measure humidity

A humidity sensor is available as an option.
Power for the sensor is also supplied from the main unit.
Equipped with a dedicated humidity range

Humidity sensor (B-530)

Digital I/O port available

Digital I / O can be used by connecting an optional I / O cable.

Input/Output cable (B-513)

Logic/Pulse inputs (4 channels)

Logic :  No-voltage contact (A contact, B contact, NO, NC) ,Open collector, Voltage input (H.L decision)
Pulse : 3 types of selections (Rotation / Quantity count / Instantaneous) per channel

<Alarm output: 4ch>

Alarm conditions can be set for each input channel.

Signal output from outputs 1 to 4 is possible in the event of an alarm.

Flexible Options with 4 Terminals

Terminal Specification Comparison

スクロールできます
WITHSTAND HIGH-VOLTAGE
HIGH-PRECISION TERMINAL
(B-565)
30CH SCREW LESS
INPUT TERMINAL
(B-563SL-30)
20CH SCREW
INPUT TERMINAL
(B-563)
20CH SCREWLESS
INPUT TERMINAL
(B-563SL)
Number of input channels20ch30ch20ch20ch
Input terminal typeM3 screw-typeScrewlessM3 screw-typeScrewless
 Input methodPhoto MOS relay scanning system
All channels isolated, balanced input
 Measurement ranges※1Voltage20・50・100・200・500mV・1・2・5・10・20・50・100V、1-5V F.S.
TemperatureThermocouples:K, J, E, T, R, S, B, N, C (W: WRe5-26)
RTD (only 3 wire type is supported) : Pt100, JPt100, Pt1000(IEC751)(* RTD cannot be connected.)
Temperature range: 100°C, 500°C, 2000°C (In the case of Fahrenheit: 150°F, 750°F, 3000°F)
Humidity0 to 100% (Optional humidity sensor B-530 is required)
 Maximum permissible input voltageBetween +/– terminals20mV to 2V range (60Vp-p)
5V to 100V range (110Vp-p)
Between input terminal/input terminal600Vp-p60Vp-p
Between input terminal/GND300Vp-p60Vp-p
 Withstand voltageBetween input terminal/input terminal600Vp-p350Vp-p 1 minute
Between input terminal/GND2300VACrms 1 minute350Vp-p 1 minute
 Voltage measurement accuracy± (0.05% of F.S. +10μV)±0.1% of F.S.
Operating environment0~45℃
 Dimensions(*including GL860)240×166×52.5mm (exclude protrusion)240×158×52.5mm (exclude protrusion)
 Weight(*including GL860)1035g (exclude AC adapter & battery)1010g(exclude AC adapter & battery)

*Please refer to the user manual for the measurement accuracy of each terminal.

Maximum input voltage

B-565
< Between +/– terminals (A) >
– Maximum input voltage: 60Vp-p (Range of 20mV to 2V)
110Vp-p (Range of 5V to 100V)
< Between input terminal/input terminal (B) >
– Maximum input voltage: 600Vp-p
– Withstand voltage: 600Vp-p
< Between input terminal/GND (C) >
– Maximum input voltage: 300Vp-p
– Withstand voltage: 2300Vp-p at 1 minute

B-563SL-30 / B-563 / B-563SL
< Between +/– terminals (A) >
– Maximum input voltage: 60Vp-p (Range of 20mV to 2V)
         110Vp-p (Range of 5V to 100V)
< Between input terminal/input terminal (B) >
– Maximum input voltage: 60Vp-p
– Withstand voltage: 350Vp-p at 1 minute
< Between input terminal/GND (C) >
– Maximum input voltage: 60Vp-p
– Withstand voltage: 350Vp-p at 1 minute

Channel Expansion of Analog Signal Input Port

Expandable up to 200 channels.

Example

20ch / 30ch

0ch or more (up to 200ch)

Example of channel expansion

スクロールできます
Number of channels20ch40ch60ch100ch200ch
GL86011111
Connection cable for extension terminal
(B-567-05/B-567-20)
1111
Base unit for input terminal(B-566)23510
20ch terminal*1
(B-565/B-563/B-563SL)
123510

*1. When using B-565 with other terminals,
Withstand voltage: lower withstand voltage will be applied
Accuracy: depends on the terminal

The input terminal and GL860 can be extended by using the connection cable for extension terminal (50cm / 2m)

*If the measurement is affected by noise, slow down the sampling interval.

CH copy function is useful for multi-channel measurements

Copy settings such as input, range, filter, EU, etc. at once.
The setup can be done simply by selecting a channel, greatly reducing the man-hours required.
Trigger and alarm settings can also be copied

Maximum Sampling Interval of Up to 5ms

Up to 5ms sampling speed is achievable when limiting the number of channels in use.

スクロールできます
 Sampling Interval5ms10ms20ms50ms100ms250ms500ms1s
 Sampling Interval124102050100200
MeasuringVoltage / Humidity
Temperature

Built-in 8GB Flash Memory with SD Card Support

Example of recording time (data size: 2GB)

スクロールできます
 Sampling Interval5ms10ms50ms100ms200ms500ms1s10s
GBD format15 days24 days47 days54 days108 days270 days366+ days366+ days
CSV format1 day3 days8 days11 days22 days55 days111 days366+ days

*Figures are approximate. File size of captured data is 2GB in GBD or CSV file format on this chart.
5ms: 1ch, 10ms: 2ch, 20ms: 4ch, 50ms: 10ch

Ring capture function

The most recent data is saved when the memory is configured in ring memory mode. (Number of capturing data is 1000 to 2000000 points)

Relay capture function

Data is continuously saved to multiple files up to 2GB without losing any data until capturing is stopped when the memory is configured in the relay mode.

Memory loop function

In addition to the existing relay capture function, the oldest file is automatically deleted before memory capacity runs out.

Hot-swapping the SD memory card

SD card can be replaced during data capturing when the sampling interval is 100ms or slower.
*When the wireless LAN is installed, the SD memory card cannot be inserted into the SD CARD slot.

Back up recording data

The data file can be created periodically for purpose of backing up data while recording it, and the file is automatically transferred to another storage device on the unit or FTP server on the network.

Backup interval: 1, 2, 6, 12, 24 hour(s)
Backup file destination: SD memory card or FTP server
Data file format: GBD (binary) or CSV (text)

The CSV format is available with firmware version 1.43 or rater.
• Available sampling speed is the 100 ms or slower when using the CSV format.
• When the RING mode or external pulse synchronization sampling is selected for recording, the backup function is not available.
• The storage device specified as the recording destination of the measurement data can not be set as the transfer destination of the backup file.
• When backup is enabled and data file format is specified with CSV format, SD memory card exchange (hot-swapping) and RELAY recording are not available.

Data file verification

It is a function to check the integrity of the data file when replaying the data file. It compares check-sum generated from the data file and recorded check-sum. When two check-sums do not match, the data file may be corrupted or has been changed by someone. The check-sum code is recorded into the file when data file is created by the GL unit.

• Check-sum code is added to normal data recording file and also file created for backup, ring or relay recording. Adding check-sum is available for data files created in GBD format. When the recorded data file is converted and saved using GL100_240_840-APS or GL-Connection software, the check-sum code will not match.

• This function is available with firmware version 1.43 or rater.

Multiple PC Interfaces Depending on Measurement Environment

Connection to your PC can be made via USB, wireless LAN or wired LAN.
*Optional B-568 is required for wireless LAN connection. The USB connection is a common A-B type cable.

Wireless connection with PC using Optional Wireless LAN unit (B-568)

*Optional Wireless LAN unit is available in limited region.

Wireless LAN option enables the wireless communication with the other devices.

Access Point enables direct connection to PCs and smart devices without a router.
Station enables connection to a wireless LAN router. Depending on the environment, data can be checked and e-mails can be received with remote PCs and smart devices via the Internet.

Wired connection with PC by Ethernet (10BASE-T / 100BASE-TX)

One-to-one connection with a PC or multiple connections via a HUB are possible.

Modbus/TCP

Data recorded by GL860 can be transferred to PLC via Modbus communication.
Recording start/stop control of GL860 is available from PLC. For more information on Modbus communication, please apply us for the SDK.

New service “G-REMOTE” *Additional charge for use.

Remote control and data capture can be easily performed using a web browser from anywhere with an Internet connection.
The recorded data can be backed up to a dedicated cloud server.

Useful Functions

Useful functions

  • Alarm output function
  • Alarm history function
  • Improved Inter-CH calculation
  • AUTO span
  • USB drive mode
  • 3 Types of power source

Operability improvements

  • Accelerated Web server function
  • Simplified waveform setup
  • Hide unnecessary menus
  • Display HELP QR Code
  • Improved visibility (Improved MENU tree)

SENSOR & CABLE